Oceanic Personal Dive Computer Veo 100Nx Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Počítače Oceanic Personal Dive Computer Veo 100Nx. Oceanic Personal Dive Computer Veo 100Nx User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 72
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 2 - DECOMPRESSION MODEL

10Oxygen Accumulation Bar Graph (O2BG)Variable Ascent Rate Indicator (VARI)WARNING: At depths greater than 60 FT (18 M),ascent rates should not excee

Strany 3 - CONTENTS

11ALPHA / NUMERIC DISPLAYSDepth DisplaysFig. 4 - MAX DEPTHaaFig. 3 - CURRENT DEPTH

Strany 4 - CONTENTS (continued)

12Time DisplaysTemperature DisplayNOTE: The Informational Displays are described indetail as the various operating modes they appear inare presented

Strany 5

13POWER SUPPLYBattery IndicatorLow Battery ConditionFig. 8 - LOW BATTERYFig. 7 - BATTERY ICONa

Strany 6 - LCD DISPLAY

14RESPONSIBLEDIVER

Strany 7 - FEATURES and DISPLAYS

15FO2 MODESetting FO2 is described on Page 21.Fig. 9 - FO2 Set for AIRFig. 10 - FO2 Set for 21%

Strany 8 - CONTROL BUTTON

16Fig. 11 - FO2 Default ONFig. 12 - FO2 Default OFFFO2 50% DEFAULT

Strany 9 - Fig. 1 - TLBG

17ACTIVATION and SETUPWARNING: Prior to diving with the Veo 100Nx, you must alsoread and understand the Oceanic Dive Computer Safety andReference Man

Strany 10 - Fig. 2 - O2BG and VARI

18ACTIVATIONWARNING: If the unit is activated at elevationshigher than 14,000 feet (4,270 meters), it will per-form a diagnostic check and immediatel

Strany 11 - Depth Displays

19Wet Contact Activation (only if Wet Activation is set ON)SURFACE SEQUENCESURFACE MODEFig. 15 - SURFACE MODE(module is dry)a

Strany 12 - Fig. 6 - TEMPERATURE

2LIMITED TWO-YEAR WARRANTYCOPYRIGHT NOTICETRADEMARK NOTICEPATENT NOTICEDECOMPRESSION MODEL

Strany 13 - Low Battery Condition

20SET MODEFig. 17 - SET MODE ENTRYFig. 16 - SURFACE MODE(module is wet)

Strany 14

21Fig. 18 - FO2 set for AIRFig. 19 - FO2 set for 32%(130 feet allowed)a

Strany 15 - FO2 MODE

22Fig. 20 - SET WETACTIVATION

Strany 16 - FO2 50% DEFAULT

23Fig. 21 - SET UNITS OFMEASURE

Strany 17 - ACTIVATION and SETUP

24Fig. 22 - SET HOURFORMAT

Strany 18 - ACTIVATION

25Fig. 23 - SET TIME

Strany 19 - SURFACE MODE

26Fig. 24 - SET PO2 ALARM

Strany 20 - SET MODE

27Fig. 25 - SET FO2 DEFAULT

Strany 21 - (130 feet allowed)

28SUMMARY OF PRE DIVE SETUPNOTE: The Veo 100Nx will enter Dive Mode upon descent to 5 FT (1.5 M) iffirst activated by push button or if Wet Activatio

Strany 22 - Fig. 20 - SET WET

29PLAN and DIVE MODESWARNING: Prior to diving with the Veo 100Nx, you must alsoread and understand the Oceanic Dive Computer Safety andReference Manu

Strany 24 - Fig. 22 - SET HOUR

30PRE DIVE PLANNING SEQUENCETMWARNING: The available dive times provided areonly predictions, depending on cylinder size and airconsumption rate, yo

Strany 25 - Fig. 23 - SET TIME

31NOTE: The Veo 100Nx will store O2 accumulationcalculations for up to 10 dives conducted during a 24hour period. If the maximum limit for oxygen l

Strany 26 - Fig. 24 - SET PO2 ALARM

32TLBG (TISSUE LOADING BAR GRAPH) (Fig. 28a)O2BG (OXYGEN ACCUMULATION BAR GRAPH) (Fig. 28b)VARI (VARIABLE ASCENT RATE INDICATOR) (Fig. 28c)Fig. 28 - B

Strany 27 - Fig. 25 - SET FO2 DEFAULT

33CONTROL OF DISPLAYSNO DECOMPRESSION DIVE MODENo Deco Dive Main Display #1 (Fig. 30)Fig. 30 - NO DECO MAIN #1No DecoMode icon

Strany 28 - SUMMARY OF PRE DIVE SETUP

34No Deco Dive Main Display #2 (Fig. 31)No Deco Dive Main Display #3 (Fig. 32)Fig. 31 - NO DECO MAIN #2Fig. 32 - NO DECO MAIN #3

Strany 29 - PLAN and DIVE MODES

35No Deco Dive Main Display #4 (Fig. 33)No Deco Dive SAFETY STOP (Fig. 34)Fig. 33 - NO DECO MAIN #4Fig. 34 - NO DECO SAFETYSTOP

Strany 30

36DECOMPRESSION DIVE MODETotal Ascent TimeManaging Decompression StopsFig. 35 - ENTRY into DECO DecoMode iconaFig. 36 - DECO STOPbcd

Strany 31 - Fig. 26 - NITROGEN IN

37Deco Dive Main (Default) Display (Fig. 37)Fig. 37 - DECO STOP MAIN

Strany 32 - Fig. 29 - ASCENT TOO FAST

38Deco Dive Alternate Display 1 (Fig. 38)Deco Dive Alternate Display 2 (Fig. 39)Deco Dive Alternate Display 3 (Fig. 40)Fig. 38 - DECO STOP ALT 1Fig. 4

Strany 33 - NO DECOMPRESSION DIVE MODE

39VIOLATION MODESConditional Violation ModeFig. 41 - CONDITIONALVIOLATIONab

Strany 34 - Fig. 32 - NO DECO MAIN #3

4CONTENTS (continued)SET MODE ...

Strany 35 - Fig. 34 - NO DECO SAFETY

40Delayed Violation Mode #1 (Fig. 42)Delayed Violation Mode #2 (Fig. 43)Fig. 42 - DELAYEDVIOLATION #1Fig. 43 - DELAYEDVIOLATION #2

Strany 36 - Fig. 36 - DECO STOP

41Delayed Violation Mode #3 (Fig. 44)Immediate Violation and Violation Gauge ModeFig. 44 - DELAYEDVIOLATION #3Fig. 45 - VIOLATION GAUGEMODE

Strany 37 - Fig. 37 - DECO STOP MAIN

42NOTE: This condition is a Permanent Violation, andin the event that a dive is made during the 24 hourperiod, a full 24 hour surface interval must t

Strany 38 - Fig. 39 - DECO STOP ALT 2

43HIGH PO2Fig. 47 - HIGH PO2WARNINGFig. 48 - HIGH PO2 ALARM

Strany 39 - Conditional Violation Mode

44HIGH OXYGEN ACCUMULATIONFig. 49 - HIGH O2

Strany 40 - VIOLATION #2

45POST DIVE MODESWARNING: Prior to diving with the Veo 100Nx, you must alsoread and understand the Oceanic Dive Computer Safety andReference Manual,

Strany 41 - Fig. 45 - VIOLATION GAUGE

46POST DIVE SURFACE MODETRANSITION PERIODFig. 50 - TRANSITIONPERIODFig. 51 - LOG MODE(during Transition Period)

Strany 42 - (on Surface)

47AFTER THE TRANSITION PERIOD (THE FIRST 2 HOURS)Time to Fly/DesaturateFig. 52 - TIME TO FLYFig. 53 - DESAT TIME

Strany 43 - HIGH PO2

48Pre Dive Planning Sequence (PDPS)Fig. 54 - ADJUSTED NDLs

Strany 44 - HIGH OXYGEN ACCUMULATION

49Log ModeFig. 55 - LOG PREVIEW

Strany 45 - POST DIVE MODES

5CONTENTS (continued)POST DIVE MODES ... 45POST DI

Strany 46 - TRANSITION PERIOD

50Fig. 57 - LOG O2 DATAFig. 56 - LOG DIVE DATA

Strany 47 - Time to Fly/Desaturate

51AFTER THE FIRST 2 HOURSFig. 58 - FLY/SATFig. 59 - SURFACE MODE (greater than 9:59)

Strany 48 - Fig. 54 - ADJUSTED NDLs

52WET CONTACTSFig. 60 - SURFACE MODE (unit wet)Fig. 61 - DESAT (unit wet)

Strany 49 - Log Mode

53RESET (CLEAR) FEATUREWARNING: Reset after a dive and subsequent use for a repetitive dive con-ducted by the same diver could result in serious inju

Strany 50 - Fig. 56 - LOG DIVE DATA

54UNEXPECTED LOSS OF DISPLAYED INFORMATIONRESPONSIBLEDIVERBe a -RESPONSIBLE DIVERat all times.

Strany 51 - AFTER THE FIRST 2 HOURS

55GENERALWARNING: Prior to diving with the Veo 100Nx, you must alsoread and understand the Oceanic Dive Computer Safety andReference Manual, Doc. No.

Strany 52 - WET CONTACTS

56CARE AND CLEANINGINSPECTIONS AND SERVICEFig. 63 - BACK OF CASEa

Strany 53 - RESET (CLEAR) FEATURE

57To Obtain ServiceNOTE: The procedures that follow must be closelyadhered to. Damage due to improper battery replace-ment is not covered by the uni

Strany 54 - RESPONSIBLE DIVER

58MODULE REMOVAL FROM BOOTBATTERY REPLACEMENTNOTE: If the old Battery can be removed and the new one inserted within 8seconds, nitrogen and oxygen ca

Strany 55

59Battery Hatch RemovalBattery RemovalInspectionFig. 64 - RING REMOVALFig. 65 - HATCH REMOVALabc

Strany 56 - INSPECTIONS AND SERVICE

6LCD DISPLAYComponents:a. Icon - Operating Modeb. Icon - Descend ArrowIcon - Deco Ceiling Stop BarIcon - Ascend Arrowc. Graphic - Maximum PO2d. Tissue

Strany 57 - To Obtain Service

60WARNING: If damage or corrosion is found, returnyour Veo 100Nx to an Authorized Oceanic Dealer, andDO NOT attempt to use it until it has received f

Strany 58

61Fig. 68 - O-RING ORIENTA-TIONFig. 70 -TIGHTENING theRETAINING RINGFig. 69 -ENGAGING theRETAINING RING TABSa

Strany 59 - Fig. 65 - HATCH REMOVAL

62InspectionWARNING: If there are any portions of the displaymissing or appearing dim, or if a Low Battery condi-tion is indicated, return your Veo 1

Strany 60 - RETAINING BAR

63ALTITUDE COMPENSATIONWARNING: The Veo 100Nx will not sense ambient pressures or provideAltitude compensation when it is wet. DO NOT dive at any di

Strany 61

64CAN BE USED AS Air Computer Nitrox ComputerNO DECOMPRESSION MODELBasis: Modified Haldanean Algorithm 12 tissue compartmentsData Base: Diving Sc

Strany 62 - Responsible

65OPERATIONAL MODES (continued) Decompression Dive: Main - Default (Depth, Stop Depth and Time, Total Ascent Time, Bar Graphs) Alternate #1 (Depth

Strany 63

66Special Displays: Occurrence Diagnostic Display After Manual Activation Serial Number Display After Diagnostics (if the Button is held depressed u

Strany 64 - SPECIFICATIONS

67SPECIFICATIONS (CONTINUED)OPERATIONAL PERFORMANCE (continued)Dive Log Mode: Stores 12 most recent dives in memory for viewing After 12 dives, adds

Strany 65 - SPECIFICATIONS (CONTINUED)

68OPERATIONAL PERFORMANCE (continued)Shut Off: Automatically shuts Off if no dive is made within 2 hours after initial activation. Reactivation requ

Strany 66

69NOTES

Strany 67

7FEATURES and DISPLAYSWARNING: Prior to diving with the Veo 100Nx, you must alsoread and understand the Oceanic Dive Computer Safety andReference Man

Strany 68

70OCEANIC WORLD WIDEOCEANIC USA2002 Davis StreetSan Leandro, CA 94577Tel: 510/562-0500Fax: 510/569-5404Web site: http://www.OceanicWorldwide.comser

Strany 69

71SERVICE RECORDSerial No. & Rev. No. __________________Date of Purchase _____________________Purchased From _____________________Below to be fill

Strany 71 - SERVICE RECORD

8INTRODUCTIONCONTROL BUTTONRESPONSIBLEDIVERBe a - RESPONSIBLE DIVER at all times.

Strany 72

9BAR GRAPHSTissue Loading Bar Graph (TLBG)NOTE: Displays associated with oxygen and the O2Bar Graph will only appear if FO2 has been set at avalue ot

Komentáře k této Příručce

Žádné komentáře