No Decompression Dive Mode - Secondary Display (Fig. 53)
To view, press the Left (Advance) button for 2 seconds.
Information includes Current Depth, Air Time Remaining
(and Mode icon), and applicable bar graphs.
The Display will remain on the screen for 3 seconds then
revert back to the Display previously selected (#1, 2, 3, 4).
No Decompression Dive Mode - SAFETY STOP (Fig. 54)
Upon ascending to 20 feet (6 meters) on any No Decompres-
sion dive in which depth exceeded 30 feet (9 meters), a short
beep will be emitted and a Safety Stop at 15 feet (4.5
meters) will appear on the display with a 3 minute count-
down timer that counts down from 3:00 to :00 (min:sec).
The Safety Stop will be displayed until the countdown times
out, or the diver descends below 30 feet (10 meters), or the
diver surfaces. There is no Penalty if the diver surfaces prior
to completing the Safety Stop.
Information includes Current Depth, Stop Depth (15 feet or
4.5 meters), Stop Bar icon, Countdown Timer, Dive Time
Remaining, Cylinder Pressure, and applicable bar graphs.
Fig. 54 - No Deco Safety Stop